Sign In | Join Free | My himfr.com
Home > Differential Pressure Transducers >

PPM-WCY61 2 Wire 20mA Differential Pressure Transducers

    Buy cheap PPM-WCY61 2 Wire 20mA Differential Pressure Transducers from wholesalers
     
    Buy cheap PPM-WCY61 2 Wire 20mA Differential Pressure Transducers from wholesalers
    • Buy cheap PPM-WCY61 2 Wire 20mA Differential Pressure Transducers from wholesalers
    • Buy cheap PPM-WCY61 2 Wire 20mA Differential Pressure Transducers from wholesalers

    PPM-WCY61 2 Wire 20mA Differential Pressure Transducers

    Ask Lasest Price
    Brand Name : CSPPM
    Model Number : PPM-WCY61-P050A
    Certification : CE
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 1000 pcs per month
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    PPM-WCY61 2 Wire 20mA Differential Pressure Transducers

    PPM-WCY61-P050A Infectious Disease Room Differential Pressure Transducer

    Product Introduction:
    It is consisted of stainless steel diaphragm and gilt ceramic fixed electrode. When pressure changes, the space between two electrode pad also changes, which result in the change in capacitance value. And then the unique detective circuit will transfer the change of capacitance value into linear DC signal.
    inherit the consistent characteristics of high-precision, rapid-response and low range. Considering the requirement of pharmaceutical plant and clean room for low differential pressure transducer, on-site LCD is developed and accessories with non-dust accumulation surface are added to meet the industrial applying requirement; so it is a desire choice for pharmaceutical plant, clean rooms of electronic factory and no-dust laboratory. low differential pressure transducer can measures pressure difference or gauge pressure (static pressure) and can choose the output signal in 4-20mA, 0-5VDC or 0-10VDC. transducer has conducted temperature compensation with an exciting voltage of 24VDC and can choose 24VAC as power supply for voltage signal product. The minimum measurement of Model 261C range is at 0 ~ 25Pa with an accuracy of ±1%FS at room temperature; The unit are temperature compensated to ±0.06%FS/°C thermal error over the temperature range +5 to +65°C.

    Applications :
    Pharmaceutical Plant
    Clean Room
    Bio-Safety Labs
    Infectious Disease Room
    Stairwell Fire and Smoke Protection

    Technical Parameters :

    Parameter

    Accuracy RSS* (constant temperature)

    Standard

    ±1.0%FS

    Option

    ±0.4%FS

    Option

    ±0.25%FS

    Non-Linearity, BFSL±0.98%FS±0.33%FS±0.20%FS
    Non-Repeatability±0.05%FS±0.05%FS±0.05%FS
    Hysteresis±0.1%FS±0.1%FS±0.1%FS
    Compensation range-5 ~ +65°C (no LCD display)
    Zero/ Span shift<0.06%FS/°C
    Max. linear pressure70KPa
    OverpressureUp to 70KPa in positive or negative direction
    Warm up drif±0.1% FS

    Error caused by installing position

    (the nominal position in factory is in vertical position)

    RangeZero Drift (%FS/G)
    0-25Pa2.1
    0-250Pa0.22
    0-1250Pa0.14
    0-7500Pa0.06

    * RSS of non-linear, hysteresis and non-repeatability



    Environmental and Physical Data

    Operating-18 ~ +65°C
    Storage-54 ~ +82°C
    Electrical connectionPG-9 cable locking device
    Pressure Fitting

    3/16” O.D.Barbed Brass pressure fitting for

    1/4” push-on tubing

    Zero and Span adjustmentsAccessible Inside of Case
    Pressure mediumAir or similar non-conducting gas
    EnclosureCast aluminum
    Weight347.5g
    Mountingφ3mm bolt or countersunk head bolt (option)


    Electrical Data (Voltage)

    Circuit3-Wire (Com, Exc, Out)
    Exciting

    9 ~ 30VAC/12 ~ 42VDC (0 ~ 5VDC output);

    12 ~ 30VAC/13 ~ 42VDC (0 ~ 10VDC output)

    Output*0-5VDC/0-10VDC**
    Bidirectional Output at Zero2.5VDC(0-5VDC) / 5VDC(0-10VDC)
    Output Impedance100Ω

    *Calibrated into a 50KΩ load, operable into a 5KΩor greater.
    ** Zero output factory set to within ±50mV (± 25mV for option accuracy)
    ** Span(Full scale) output factory set to within ±50mV (± 25mV for option accuracy)

    Electrical Data (Current)

    Circuit2-Wire Protected from Miswiring
    Full scale output*20mA±0.16mA
    Zero point output*4mA±0.16mA
    Bidirectional Output at Zero12mA
    External load0-800Ω
    Min. supply voltage9+0.02×(Resistance of receiver plus line)VDC
    Max. supply voltage30+0.004 × (Resistance of receiver plus line)VDC

    * Calibrated with a 24VDC loop supply voltage and a 250 ohm load

    Definition of wiring:

    Dimensions in mm :

    Quality PPM-WCY61 2 Wire 20mA Differential Pressure Transducers for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Changsha Taihe Electronic Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)